Bristol
Showing all 9 results
-
338 Series Optical Wavelength Meter
Reliably accurate optical transceiver testing
- Fast measurement rate of 25 Hz
- Wavelength accuracy as high as ± 0.3 pm
- Continuous calibration with built-in wavelength standard
- Measurement confidence level ≥ 99.7%
- Traceable to NIST standards
- Power measured to an accuracy of ± 0.5 dB
- Wavelength range from 1270 to 1680 nm
- Operates with CW and modulated signals
- Convenient touch-screen display reports measurement data in a variety of formats
- Interfacing via SCPI using USB, Ethernet, or GPIB
- Rugged design for manufacturing environments
- 5-year warranty covers all parts and labor
-
438 Series Multi-Wavelength Meterv
Fast, accurate, and versatile WDM testing
- Wavelength accuracy as high as ± 0.3 pm
- Continuous calibration with built-in wavelength standard
- Measurement confidence level ≥ 99.7%
- Traceable to NIST standards
- Power measured to an accuracy of ± 0.5 dB
- Reports OSNR to > 40 dB
- Automatically calculates SMSR
- Fastest measurement rate of 10 Hz
- Wavelength range from 1000 to 1680 nm
- Operates with CW and modulated signals
- Convenient touch-screen display reports measurement data in a variety of formats
- Software is available to convert the system to a high-resolution OSA
- Interfacing via SCPI using USB, Ethernet, or GPIB
- Rugged design for manufacturing environments
- 5-year warranty covers all parts and labo
-
671 Series Laser Wavelength Meter
Reliable accuracy from the visible to mid-IR
- Wavelength accuracy as high as ± 0.0001 nm
- Continuous calibration with built-in wavelength standard
- Operation available from 375 nm to 12 μm
- Convenient pre-aligned fiber-optic input for wavelengths up to 2.6 μm
- Free-space aperture input with visible alignment aid for IR and mid-IR wavelengths
- Straightforward operation with PC using USB or Ethernet
- Display software provided to control measurement parameters and report wavelength data
- Automatic data reporting using custom or LabVIEW programming eliminates the need for a dedicated PC
- 5-year warranty covers all parts and labor
-
771 Series Laser Spectrum Analyzer
The most complete laser spectral characterization from the visible to the mid-IR
- Spectral resolution as high as 2 GHz
- Wavelength accuracy as high as ± 0.0001 nm
- Continuous calibration with built-in wavelength standard
- Optical rejection ratio > 40 dB
- Operation available from 375 nm to 12 μm
- Supports CW and high-repetition rate pulsed lasers
- Convenient pre-aligned fiber-optic input for wavelengths up to 2.6 μm
- Free-space aperture input with visible alignment aid for IR/mid-IR wavelengths
- Straightforward operation with a PC using USB or Ethernet
- Display software provided to control measurement parameters, display spectra, and report wavelength data
- 5-year warranty covers all parts and labor
-
772B-MIR Pulsed Laser Spectrum Analyzer
Spectral characterization of pulsed IR and mid-IR lasers
- Operation from 1 to 12 μm
- Spectral resolution of 4 GHz
- Wavelength accuracy of ± 10 parts per million
- Continuous calibration with a built-in wavelength standard
- Optical rejection ratio as high as 20 dB
- Free-space aperture input with visible alignment aid
- Straightforward operation with a PC using USB or Ethernet
- Display software provided to control measurement parameters, display spectra, and report wavelength data
- 5-year warranty covers all parts and labor
-
828 Series Optical Wavelength Meter
Fast wavelength measurement reduces testing times
- Fastest sustained measurement rate of 1 kHz
- Wavelength accuracy as high as ± 0.3 pm
- Automatic calibration with built-in wavelength standard
- Measurement confidence level ≥ 99.7%
- Traceable to NIST standards
- Power measured to an accuracy of ± 0.5 dB
- Wavelength range from 1250 to 1650 nm
- Convenient touch-screen display reports measurement data in a variety of formats
- Data streaming available using RS-422 serial interface
- Internal data storage for up to one million measurements
- Interfacing via SCPI using USB, Ethernet, or GPIB
- Rugged design for manufacturing environments
- 5-year warranty covers all parts and labor
-
871 Series Laser Wavelength Meter
Fast, accurate, and reliable wavelength measurement for pulsed and CW lasers
- Wavelength accuracy as high as ± 0.0001 nm
- Automatic calibration with built-in wavelength standard
- Operation available from 375 nm to 2.5 μm
- Sustained measurement rate of 1 kHz
- Convenient pre-aligned fiber-optic input
- Asynchronous operation with automatic pulse detection
- Straightforward operation with PC using
USB or Ethernet - Display software provided to control measurement parameters and report
wavelength data - Automatic data reporting using custom or LabVIEW programming eliminates the need for a dedicated PC
- Built-in PID controller for precise laser stabilization
- Easily mounts into standard 19” rack (2U)
- 5-year warranty covers all parts and labor
-
872 Series Laser Wavelength Meter
Highest resolution wavelength measurement
- Frequency resolution up to 200 kHz
- Wavelength accuracy as high as ± 0.0001 nm
- Automatic calibration with a built-in wavelength standard
- Supports calibration with an external reference laser
- Operation available from 375 to 1700 nm
- Sustained measurement rate of 1 kHz
- Straightforward operation via PC using USB or Ethernet
- Automatic data reporting using custom or LabVIEW programming eliminates the need for a dedicated PC
- Built-in PID controller for precise laser stabilization
- Optional Multi-Laser PID Controller and
Fiber-Optic Switch enable the stabilization of up to 8 lasers - Easily mounts into standard 19″ rack (2U)
- 5-year warranty covers all parts and labor
End of content
End of content











