Bristol

Showing all 9 results

  • 238-Optical-Wavelength-Meter FES

    238 Series Optical Wavelength Meter

    Reliable accuracy over a broad wavelength range

    • Wavelength accuracy as high as ± 0.3 pm
    • Continuous calibration with built-in wavelength standard
    • Measurement confidence level ≥ 99.7%
    • Traceable to NIST standards
    • Power measured to an accuracy of ± 0.5 dB
    • Broad operational range of 700 to 1650 nm
    • Measurement rate of 15 Hz
    • Convenient touch-screen display reports measurement data in a variety of formats
    • Interfacing via SCPI using USB, Ethernet, or GPIB
    • Rugged design for manufacturing environments
    • 5-year warranty covers all parts and labor
  • 338 Series Optical Wavelength Meter

    338 Series Optical Wavelength Meter

    Reliably accurate optical transceiver testing
    • Fast measurement rate of 25 Hz
    • Wavelength accuracy as high as ± 0.3 pm
    • Continuous calibration with built-in wavelength standard
    • Measurement confidence level ≥ 99.7%
    • Traceable to NIST standards
    • Power measured to an accuracy of ± 0.5 dB
    • Wavelength range from 1270 to 1680 nm
    • Operates with CW and modulated signals
    • Convenient touch-screen display reports measurement data in a variety of formats
    • Interfacing via SCPI using USB, Ethernet, or GPIB
    • Rugged design for manufacturing environments
    • 5-year warranty covers all parts and labor
  • 438 Series Multi-Wavelength Meterv

    438 Series Multi-Wavelength Meterv

    Fast, accurate, and versatile WDM testing
    • Wavelength accuracy as high as ± 0.3 pm
    • Continuous calibration with built-in wavelength standard
    • Measurement confidence level ≥ 99.7%
    • Traceable to NIST standards
    • Power measured to an accuracy of ± 0.5 dB
    • Reports OSNR to > 40 dB
    • Automatically calculates SMSR
    • Fastest measurement rate of 10 Hz
    • Wavelength range from 1000 to 1680 nm
    • Operates with CW and modulated signals
    • Convenient touch-screen display reports measurement data in a variety of formats
    • Software is available to convert the system to a high-resolution OSA
    • Interfacing via SCPI using USB, Ethernet, or GPIB
    • Rugged design for manufacturing environments
    • 5-year warranty covers all parts and labo
  • 671 Series Laser Wavelength Meter

    671 Series Laser Wavelength Meter

    Reliable accuracy from the visible to mid-IR
    • Wavelength accuracy as high as ± 0.0001 nm
    • Continuous calibration with built-in wavelength standard
    • Operation available from 375 nm to 12 μm
    • Convenient pre-aligned fiber-optic input for wavelengths up to 2.6 μm
    • Free-space aperture input with visible alignment aid for IR and mid-IR wavelengths
    • Straightforward operation with PC using USB or Ethernet
    • Display software provided to control measurement parameters and report wavelength data
    • Automatic data reporting using custom or LabVIEW programming eliminates the need for a dedicated PC
    • 5-year warranty covers all parts and labor
  • 771 Series Laser Spectrum Analyzer

    771 Series Laser Spectrum Analyzer

    The most complete laser spectral characterization from the visible to the mid-IR
    • Spectral resolution as high as 2 GHz
    • Wavelength accuracy as high as ± 0.0001 nm
    • Continuous calibration with built-in wavelength standard
    • Optical rejection ratio > 40 dB
    • Operation available from 375 nm to 12 μm
    • Supports CW and high-repetition rate pulsed lasers
    • Convenient pre-aligned fiber-optic input for wavelengths up to 2.6 μm
    • Free-space aperture input with visible alignment aid for IR/mid-IR wavelengths
    • Straightforward operation with a PC using USB or Ethernet
    • Display software provided to control measurement parameters, display spectra, and report wavelength data
    • 5-year warranty covers all parts and labor
  • 772B-MIR Pulsed Laser Spectrum Analyzer

    772B-MIR Pulsed Laser Spectrum Analyzer

    Spectral characterization of pulsed IR and mid-IR lasers
    • Operation from 1 to 12 μm
    • Spectral resolution of 4 GHz
    • Wavelength accuracy of ± 10 parts per million
    • Continuous calibration with a built-in wavelength standard
    • Optical rejection ratio as high as 20 dB
    • Free-space aperture input with visible alignment aid
    • Straightforward operation with a PC using USB or Ethernet
    • Display software provided to control measurement parameters, display spectra, and report wavelength data
    • 5-year warranty covers all parts and labor
  • 828 Series Optical Wavelength Meter

    828 Series Optical Wavelength Meter

    Fast wavelength measurement reduces testing times
    • Fastest sustained measurement rate of 1 kHz
    • Wavelength accuracy as high as ± 0.3 pm
    • Automatic calibration with built-in wavelength standard
    • Measurement confidence level ≥ 99.7%
    • Traceable to NIST standards
    • Power measured to an accuracy of ± 0.5 dB
    • Wavelength range from 1250 to 1650 nm
    • Convenient touch-screen display reports measurement data in a variety of formats
    • Data streaming available using RS-422 serial interface
    • Internal data storage for up to one million measurements
    • Interfacing via SCPI using USB, Ethernet, or GPIB
    • Rugged design for manufacturing environments
    • 5-year warranty covers all parts and labor
  • 871 Series Laser Wavelength Meter

    871 Series Laser Wavelength Meter

    Fast, accurate, and reliable wavelength measurement for pulsed and CW lasers
    • Wavelength accuracy as high as ± 0.0001 nm
    • Automatic calibration with built-in wavelength standard
    • Operation available from 375 nm to 2.5 μm
    • Sustained measurement rate of 1 kHz
    • Convenient pre-aligned fiber-optic input
    • Asynchronous operation with automatic pulse detection
    • Straightforward operation with PC using
      USB or Ethernet
    • Display software provided to control measurement parameters and report
      wavelength data
    • Automatic data reporting using custom or LabVIEW programming eliminates the need for a dedicated PC
    • Built-in PID controller for precise laser stabilization
    • Easily mounts into standard 19” rack (2U)
    • 5-year warranty covers all parts and labor
  • 872 Series Laser Wavelength Meter

    872 Series Laser Wavelength Meter

    Highest resolution wavelength measurement
    • Frequency resolution up to 200 kHz
    • Wavelength accuracy as high as ± 0.0001 nm
    • Automatic calibration with a built-in wavelength standard
    • Supports calibration with an external reference laser
    • Operation available from 375 to 1700 nm
    • Sustained measurement rate of 1 kHz
    • Straightforward operation via PC using USB or Ethernet
    • Automatic data reporting using custom or LabVIEW programming eliminates the need for a dedicated PC
    • Built-in PID controller for precise laser stabilization
    • Optional Multi-Laser PID Controller and
      Fiber-Optic Switch enable the stabilization of up to 8 lasers
    • Easily mounts into standard 19″ rack (2U)
    • 5-year warranty covers all parts and labor

End of content